Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
8.5.
Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will start to avoid overcooling. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be risen by 0.5°C at the start of operation and by 0.5°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
Heating Operation When you press the SLEEP Mode, the following movement will start to avoid overheating. � The fan speed refer to Indoor Fan Motor Control. � The setting temperature will be descented by 2°C at the start of operation and by 3°C one hour later. � The operation will stop after 8 hours. � When using together with the Timer, the ON-Timer has priority.
8.6.
Auto Restart Control
� If there is a power failure, operation will be automatically restarted when the power is resumed. It will start with previous operation mode and airflow direction. (Time Delay Safety Control is valid) � Auto Restart Control is not available when Timer or Sleep Mode is set. � This control can be omitted by cutting the jumper wire J2. (Refer Circuit Diagram)
8.7.
Indoor Fan Speed Control
� Auto Fan Speed Control When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table. � Manual Fan Speed Control Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Fan Speed Cooling Soft Dry Manual Auto Sleep Manual, Auto Sleep Manual Auto Sleep O O O O High Speed �� Low Speed O O O O O O O O O O O O Lo SLo SSLo
O O
Heating
O O Hi
O O Me
O STOP
|
|
 |
> |
|